Introduction, general protocol
Digilent made a family of devboards using a common custom USB protocol. For lack of a better name, we call it the Digilent Adept protocol.
The protocol is designed to be extensible: there is a set of control requests that can be used to query information about the board and the capabilities, and then there is a common multiplexing and framing protocol used to communicate with one of the device’s “subsystems”, such as JTAG, SPI, GPIO, or board management.
The protocol is implemented by a variety of devices on the board side — some of them are ATmega based, and come up directly implementing the protocol, with upgradeability provided only by programming pins on the board. Others are FX2 based, requiring firmware upload from the host before they start speaking the protocol.
Note that Digilent has phased out this protocol — newer boards are FTDI based instead.
The protocol is implemented on devices with USB ID of 0x1443:0x0007
.
The device exposes a single configuration and single interface. The class, subclass, and protocol are all-0, as would be expected. The device has the following endpoints:
control endpoint 0: in addition to the usual core USB stuff, used to send various custom control requests
endpoint 1 OUT (bulk, 16 bytes max packet size): used to send subsystem commands
endpoint 2 IN (bulk, 16 bytes max packet size): used to receive subsystem command responses
endpoint 3 OUT (bulk, 64 bytes max packet size): used to send large data payloads for subsystem commands
endpoint 4 IN (bulk, 64 bytes max packet size): used to receive large data payloads for subsystem commands
All numbers in the protocol are encoded as little-endian unless stated otherwise.
Control requests
These control requests can be sent at any time, without any particular preparation.
A few of the requests here deal with strings. The strings are stored
on the board in fixed-length storage (different for every string),
and are NUL-terminated, except for the (legal) case of a string that takes
up the entire length of the storage. The requests will return the entire
contents of the string storage, possibly including garbage beyond the NUL
terminator (which is usually either all-NUL or all-0xff
). This garbage
should be trimmed off.
GET_PRODUCT_NAME
Returns a product name describing the board. The storage for that string is 28 bytes long.
bmRequestType
:0xc0
bRequest
:0xe1
wValue
: 0wIndex
: 0wLength
: 28
GET_USER_NAME
Returns a “user name” describing the board. It is a 16-byte string field. Allegedly it can be set by the user.
bmRequestType
:0xc0
bRequest
:0xe2
wValue
: 0wIndex
: 0wLength
: 16
SET_USER_NAME
Sets the user name of this board. It can be up to 16 bytes long. Doesn’t seem to be actually supported on all boards?
bmRequestType
:0x40
bRequest
:0xe3
wValue
: 0wIndex
: 0wLength
: 16
GET_SERIAL_NUMBER
Returns the serial number of this board. It is 12 bytes long. It can be reprogrammed by the user.
bmRequestType
:0xc0
bRequest
:0xe4
wValue
: 0wIndex
: 0wLength
: 12
SET_SERIAL_NUMBER
Sets the serial number of this board. It can be up to 12 bytes long.
bmRequestType
:0x40
bRequest
:0xe5
wValue
: 0wIndex
: 0wLength
: 12
GET_FIRMWARE_VERSION
Returns the firmware version of this board. It is a 16-bit word.
bmRequestType
:0xc0
bRequest
:0xe6
wValue
: 0wIndex
: 0wLength
: 2
GET_CAPS
Returns the capabilities of this board. It is a 32-bit word.
bmRequestType
:0xc0
bRequest
:0xe7
wValue
: 0wIndex
: 0wLength
: 4
The capabilities are a bitfield describing the available subsystems:
bit 0: DJTG
bit 1: DPIO
bit 2: DEPP
bit 3: DSTM
bit 4: DSPI
bit 5: DTWI
bit 6: DACI
bit 7: DAIO
bit 8: DEMC
bit 9: DDCI
bit 10: DGIO
SET_SECRET_HANDSHAKE
Sets a 16-bit number used in the secret handshake.
bmRequestType
:0x40
bRequest
:0xe8
wValue
: 0wIndex
: 0wLength
: 2
GET_PRODUCT_ID
Returns the binary product ID of this board. It is a little-endian 32-bit word.
bmRequestType
:0xc0
bRequest
:0xe9
wValue
: 0wIndex
: 0wLength
: 4
This word has the following bitfields:
bits 0-7: firmware identifier
bits 8-19: variant identifier
bits 20-31: product identifier
The product identifier describes the particular board. The variant identifier describes its variant, such as what FPGA size has been fitted to it.
GET_SECRET_HANDSHAKE
Gets a secret 32-bit handshake number from the board. This is a strong
cryptographic protocol used to verify the board as a genuine Digilent product.
A secret 16-bit nonce must first be set via the SET_SECRET_HANDSHAKE
request, then this request must be used to get a 32-bit MAC from the device.
bmRequestType
:0xc0
bRequest
:0xec
wValue
: 0wIndex
: 0wLength
: 4
To verify the device as a genuine Digilent board, check the MAC is correct as follows:
fn correct_mac(nonce: u16, mac: u32) -> bool {
let byte_nonce = (((nonce >> 8) ^ nonce) & 0xff) as u32;
const DIGILENT_PUBLIC_KEY: u32 = 0x69676944;
mac == (DIGILENT_PUBLIC_KEY ^ (byte_nonce | byte_nonce << 8 | byte_nonce << 16 | byte_nonce << 24))
}
Subsystem commands
All commands other than the above control requests are handled via a uniform protocol over endpoints 1-4. Commands are targetted to particular “subsystem” and a particular “port” (or, in other words, instance) of that subsystem. The following subsystems can exist:
0x00
: SYS (manages other subsystems, always present, always 1 “port”)0x01
: DMGT (general board management, always present, always 1 “port”)0x02
: DJTG (JTAG, bit 0 inGET_CAPS
)0x03
: DPIO (simple GPIO, bit 1 inGET_CAPS
)0x04
: DEPP (EPP-like parallel port, bit 2 inGET_CAPS
)0x05
: DSTM (FX2 FIFO interface, bit 3 inGET_CAPS
)0x06
: DSPI (SPI, bit 4 inGET_CAPS
)0x07
: DTWI (I²C / SMBus, bit 5 inGET_CAPS
)0x08
: DACI (UART, bit 6 inGET_CAPS
)0x09
: DAIO (analog I/O, bit 7 inGET_CAPS
)0x0a
: DEMC (electro-mechanical control, bit 8 inGET_CAPS
)0x0c
: DGIO (general sensor and user I/O, bit 10 inGET_CAPS
)
Todo
list incomplete
Commands are sent on endpoint 1, and have the following general format:
byte 0: command length in bytes, minus one
byte 1: target subsystem
byte 2:
bits 0-6: command type
bit 7:
0
: this is a short command, or the start of a long command1
: this is the end of a long command
byte 3: target port (if not applicable, set to 0)
bytes 4 and up (if any): short payload, determined by subsystem and command type
Responses to commands are received on endpoint 2, and have the following general format:
byte 0: response length in bytes, minus one
byte 1:
bits 0-5: status code
0x00
: success, payload determined by command type0x01
: command not supported (no payload)0x03
: resource in use (attempt to enable a port that is already enabled, or that uses resources shared with another enabled port), no payload0x04
: port disabled error (attempt to send a non-enable command to disabled port), no payload0x05
: DEPP address timeout (no payload)0x06
: DEPP data timeoutpayload: 32-bit number (unknown semantics)
0x0d
: command parameter out of range (no payload)0x31
: unknown subsystem (no payload)0x32
: unknown command (no payload)
bit 6: if set, a “received byte count” field is present in the reply
bit 7: if set, a “transmitted byte count” field is present in the reply
bytes 2 and up (if any): several packed fields, in order:
if status code is non-0: error payload specific to status code
if bit 7 of byte 1 set: a 32-bit word containing “transmitted byte count” (the number of bytes sent over OUT EP3 for a long command)
if bit 6 of byte 1 set: a 32-bit word containing “received byte count” (the number of bytes sent over IN EP4 for a long command)
if status code is 0: short response payload, determined by subsystem and command type
Commands and responses are short and fit in one USB packet, which can be at most 16 bytes for the relevant endpoints.
Commands come in two kinds: short and long. Whether a command is short or long depends only on its subsystem and command type. A short command simply consists of two USB transfers:
OUT EP1: command to device
IN EP2: response from device
A long command is one that possibly takes a long time and can be aborted (via the SYS_ABORT
command).
Long commands can also involve large data transfers over endpoints 3 and 4. A long consists of the following transfers:
OUT EP1: start command to device (bit 7 of byte 2 set to 0; short payload contains command arguments, if any)
IN EP2: response from device (if not successful, the command is aborted now)
OUT EP3 and/or IN EP4 (if needed): large payload to/from device (if both are needed, the two transfers may have to be overlapped)
OUT EP1: end command to device (bit 7 of byte 2 set to 1; no short payload present)
IN EP2: response from device (contains actual transmitted and received byte counts, as appropriate)
System management commands
The “subsystem” 0 (“SYS”) is special, always present, and always enabled.
SYS_ABORT
command
This command can be sent in the middle of a long command to abort the transfer.
subsystem:
0x00
(SYS)command type:
0x02
(short)port: N/A, always 0
command payload: none
response payload: none
SYS_RESET
command
This command can be sent at any time to reset the current state of the device. This involves disabling all ports.
subsystem:
0x00
(SYS)command type:
0x03
(short)port: N/A, always 0
command payload: 32-bit word
response payload: 32-bit word
For unknown reasons, this command takes a 32-bit word payload, and returns as the response payload another 32-bit word, which is equal to 0x7a - command_payload
.
General subsystem commands
These commands apply to all supported subsystems except SYS
and DMGT
.
ENABLE
command
This command enables a subsystem port, making it ready for use. The only
commands that can be sent to a disabled port are ENABLE
and
GET_CAPABILITIES
. All ports start out as disabled. A port will fail
to enable if it is already enabled, or if another port using the same hardware
resources is currently enabled.
subsystem: any except SYS and DMGT
command type:
0x00
(short)port: port index
command payload: none
response payload: none
DISABLE
command
Disables a subsystem port, undoing the ENABLE
command.
subsystem: any except SYS and DMGT
command type:
0x01
(short)port: port index
command payload: none
response payload: none
GET_PORT_PROPERTIES
command
Returns the properties of a given port of a subsystem, and also the available port count.
subsystem: any except SYS and DMGT
command type:
0x02
(short)port: port index; call with port 0 to obtain number of available ports
command payload: 1 byte: requested data byte count (can be 1 or 5)
response payload:
byte 0: port count